Automation Components Inc (ACI) A/LP2-2-20 A/LP2-2-20 - The A/LP2 Series pressure transmitters incorporate a durable piezoresistive sensing element to enable low pressure measurements. Integrated temperature compensation with offset and span calibration extends the performance of these devices to provide excellent long term reliability. The transmitters must be powered by a +18 to 36VDC or 24VAC supply. Outputs include 1 to 2 to 10VD or 4 to 20mA and are dip switch selectable. The uni-directional spans range from 0-1? to 0-20? of water column or 0-0.30kPa (300 pascals) to 0-2.5kPa (2500 pascals) and most models offer additional field selections. The A/LP2 Series has the option for an easy to read display which provides an initial set up referenc trouble shooting assistanc and performance monitoring. The cord grip fitting allows for internal wiring to a 3 pole depluggable screw terminal block. All units are calibrated using NIST certified references. In addition three and five point NIST certificates of calibration are available upon request. ACI differential air pressure sensor or transmitter are designed for HVAC Building Automation or light industrial systems. Typical applications include: building static pressur filter monitorin air flow measuremen and quarantine or isolation rooms. Field selectable ranges and output Accepts AC or DC supply voltages #Dif LP2 4-20mA No LCD
Product Description
A/LP2-2-20 - The A/LP2 Series pressure transmitters incorporate a durable piezoresistive sensing element to enable low pressure measurements. Integrated temperature compensation with offset and span calibration extends the performance of these devices to provide excellent long term reliability. The transmitters must be powered by a +18 to 36VDC or 24VAC supply. Outputs include 1 to 2 to 10VD or 4 to 20mA and are dip switch selectable. The uni-directional spans range from 0-1? to 0-20? of water column or 0-0.30kPa (300 pascals) to 0-2.5kPa (2500 pascals) and most models offer additional field selections. The A/LP2 Series has the option for an easy to read display which provides an initial set up referenc trouble shooting assistanc and performance monitoring. The cord grip fitting allows for internal wiring to a 3 pole depluggable screw terminal block. All units are calibrated using NIST certified references. In addition three and five point NIST certificates of calibration are available upon request. ACI differential air pressure sensor or transmitter are designed for HVAC Building Automation or light industrial systems. Typical applications include: building static pressur filter monitorin air flow measuremen and quarantine or isolation rooms. Field selectable ranges and output Accepts AC or DC supply voltages
#Dif LP2 4-20mA No LCD
FOR WHOLESALE ONLY — Neuco does not sell to contractors or homeowners.
If you are a contractor or homeowner, please contact your preferred distributor and refer them to Neuco to purchase on your behalf.
For help finding a local distributor, call 800.323.7394 or email [email protected] for a referral.