Automation Components Inc (ACI) A/DLP-001-WUNA0 A/DLP-001-W-U-N-A-0 - AVAILABLE MARCH 2017 Ranges (Default): 0-0.1 0-0.2 0-0.5 0-1" w.c. and ±0.1 ±0.2 ±0.5 ±1" w.c. Outputs (Default): 4-20 m 0-5 VD 0-10 VDC Display: No The DLP Series is based on a piezoresistiv silicon sensing element which senses Differential Pressure and provides an analog output. This series combines the best attributes and product flexibilities of the two product lines that it replaces (A/LP2 and A/DP2). Not only does it tap into ACI's past tradition of providing an accurate and dependable devic it has been enhanced in several important aspects. The hinged cover on the DLP can be easily opened using the integrated locking tab on the side of the enclosure. This allows for easy access to the zero function and field selectable ranges and outputs. The DLP Series also includes an optional five digi easy to read display which aids in initial setup/installatio troubleshootin and local monitoring. The cord grip fitting provides strain relief and easy access to the color code spring loaded terminal blocks. The standard accuracy of this series is ±0.5% FSO but is offered with ±0.25% and N.I.S.T. certification as well (see expanded series). Field selectable analog outputs include 0-5 and 0-10 VD or 4-20mA which correlate to a uni or bi-directional pressure range from 0-0.1? up to 0-40? of water column depending on your model selection. Each unit has up to 8 field selectabl uni or bi-directional range as well as the ability to change display units from" of water column to pascals by simply changing the internal dip switch settings. Optional Pitot Tube or Din Rail mounting further enhances the overall flexibility of this device. Applications Include: building and duct static pressur filter monitorin air flow measuremen and process control. 0-1"WC, 4-20MA DIFF PRESS TRAN
Product Description
A/DLP-001-W-U-N-A-0 - AVAILABLE MARCH 2017 Ranges (Default): 0-0.1 0-0.2 0-0.5 0-1" w.c. and ±0.1 ±0.2 ±0.5 ±1" w.c. Outputs (Default): 4-20 m 0-5 VD 0-10 VDC Display: No The DLP Series is based on a piezoresistiv silicon sensing element which senses Differential Pressure and provides an analog output. This series combines the best attributes and product flexibilities of the two product lines that it replaces (A/LP2 and A/DP2). Not only does it tap into ACI's past tradition of providing an accurate and dependable devic it has been enhanced in several important aspects. The hinged cover on the DLP can be easily opened using the integrated locking tab on the side of the enclosure. This allows for easy access to the zero function and field selectable ranges and outputs. The DLP Series also includes an optional five digi easy to read display which aids in initial setup/installatio troubleshootin and local monitoring. The cord grip fitting provides strain relief and easy access to the color code spring loaded terminal blocks. The standard accuracy of this series is ±0.5% FSO but is offered with ±0.25% and N.I.S.T. certification as well (see expanded series). Field selectable analog outputs include 0-5 and 0-10 VD or 4-20mA which correlate to a uni or bi-directional pressure range from 0-0.1? up to 0-40? of water column depending on your model selection. Each unit has up to 8 field selectabl uni or bi-directional range as well as the ability to change display units from" of water column to pascals by simply changing the internal dip switch settings. Optional Pitot Tube or Din Rail mounting further enhances the overall flexibility of this device. Applications Include: building and duct static pressur filter monitorin air flow measuremen and process control.
0-1"WC, 4-20MA DIFF PRESS TRAN
FOR WHOLESALE ONLY — Neuco does not sell to contractors or homeowners.
If you are a contractor or homeowner, please contact your preferred distributor and refer them to Neuco to purchase on your behalf.
For help finding a local distributor, call 800.323.7394 or email [email protected] for a referral.