No images available.
Automation Components Inc (ACI) A/CTA-250 A/CTA-250 - The A/CTA Series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear and proportional 4 to 20 mA output signa which can be monitored by your Building Managemen DD or PLC controller. The A/CTA Series current sensors are available in either an Average or True RMS output version. All of these sensors have jumper selectable input ranges except for the 0 to 5 Amp input range on the A/CTA-05 series sensors. The A/CTA series current sensors are fast acting and extremely accurate from 1 to 100% of the Full Scale Output. All of the A/CTA series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. They must be externally powered using a +12 to 30 VDC power supply. The A/CTA-250 Series has jumpers for 0-10 0-20 and 0-250Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems. Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges
Product Description
A/CTA-250 - The A/CTA Series current sensors monitor the current flowing to electrical equipment or buildings. The magnitude of this current is then converted into a linear and proportional 4 to 20 mA output signa which can be monitored by your Building Managemen DD or PLC controller. The A/CTA Series current sensors are available in either an Average or True RMS output version. All of these sensors have jumper selectable input ranges except for the 0 to 5 Amp input range on the A/CTA-05 series sensors. The A/CTA series current sensors are fast acting and extremely accurate from 1 to 100% of the Full Scale Output. All of the A/CTA series current sensors are factory calibrated using a NIST Traceable standard and shipped with the jumper placed in the largest jumper selectable range. They must be externally powered using a +12 to 30 VDC power supply. The A/CTA-250 Series has jumpers for 0-10 0-20 and 0-250Amps. ACI analog current sensors or transmitters are designed for HVAC Building Automation or industrial systems. Typical applications include: VF building load and load trending equipment. Patented 35mm Din-rail mounting flange Jumper selectable ranges
FOR WHOLESALE ONLY — Neuco does not sell to contractors or homeowners.
If you are a contractor or homeowner, please contact your preferred distributor and refer them to Neuco to purchase on your behalf.
For help finding a local distributor, call 800.323.7394 or email [email protected] for a referral.