No images available.
Automation Components Inc (ACI) A/ASCSX A/ASCSX - The A/ASCS and A/ASCSX series current switches are available in a split-core with either Normally-Open (N/O) or Normally-Closed (N/C) output configurations. All of these sensors will have a solid-state output with an adjustable trip point (setpoint). These current switches are ideal for providing status information on any type of AC current using equipment. These current switches should be used in applications in which a current switch with adjustable trip point is required. A change in the operating current may indicate motor failur belt loss/slippag or mechanical failure. Any time one of these events occur the current can significantly increase or decreas thus tripping the sensor and notifying the Building Management System of an alarm condition. The A/ASCS and A/ASCSX series current switches can be used to monitor devices with a maximum continuous operating current of 200 to 250 Amps depending on the model. These current switches will not need to be externally powere since the power for the switch is induced from the conductor being monitored. Another great feature of the A/ASCS and A/ASCSX series current switches is that they include a Red and Green LED that will indicate the ?Status? of the switch contacts. The ASCSX series current switches have an adjustable trip point of 3.0 to 250 Amps. ACI adjustable current status switches are designed for HVAC Building Automation or industrial systems. Typical applications include: go/no g direct drive fan pump heating element critical motor lighting circuit overload underload filter statu and belt loss or slippage. Patented 35mm Din-rail mounting flange Red and green LCD indication
Product Description
A/ASCSX - The A/ASCS and A/ASCSX series current switches are available in a split-core with either Normally-Open (N/O) or Normally-Closed (N/C) output configurations. All of these sensors will have a solid-state output with an adjustable trip point (setpoint). These current switches are ideal for providing status information on any type of AC current using equipment. These current switches should be used in applications in which a current switch with adjustable trip point is required. A change in the operating current may indicate motor failur belt loss/slippag or mechanical failure. Any time one of these events occur the current can significantly increase or decreas thus tripping the sensor and notifying the Building Management System of an alarm condition. The A/ASCS and A/ASCSX series current switches can be used to monitor devices with a maximum continuous operating current of 200 to 250 Amps depending on the model. These current switches will not need to be externally powere since the power for the switch is induced from the conductor being monitored. Another great feature of the A/ASCS and A/ASCSX series current switches is that they include a Red and Green LED that will indicate the ?Status? of the switch contacts. The ASCSX series current switches have an adjustable trip point of 3.0 to 250 Amps. ACI adjustable current status switches are designed for HVAC Building Automation or industrial systems. Typical applications include: go/no g direct drive fan pump heating element critical motor lighting circuit overload underload filter statu and belt loss or slippage. Patented 35mm Din-rail mounting flange Red and green LCD indication
FOR WHOLESALE ONLY — Neuco does not sell to contractors or homeowners.
If you are a contractor or homeowner, please contact your preferred distributor and refer them to Neuco to purchase on your behalf.
For help finding a local distributor, call 800.323.7394 or email [email protected] for a referral.